ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)
Built-in Controller Version
| Number of Positioning Data Sets | - 64 | 
| Positioning Operation | - One-shot operation, Linked operation, Linked operation 2, Sequential mode, Direct mode | 
| Other Operation | - Continuous Operation, JOG Operation, Return-to-Home Operation, Test Operation | 
| Protocol | - Modbus Protocol (Modbus RTU mode) | 
| Electrical Characteristics | -
                                                                                          EIA-485 compliance Twisted-pair wire (TIA/EIA-568B CAT5e or greater recommended) is used up to a total extension length of 50 m. | 
| Transmission/Reception Mode | - Half-duplex communication | 
| Baud Rate | - 9600 bps/19200 bps/57600 bps/115200 bps | 
| Physical Layer | - Asynchronous mode (data: 8-bit, stop bit: 1-bit/2-bit, parity: none/odd/even) | 
| Connection Type | - Up to 31 units can be connected to one programmable controller (master equipment). | 