Oriental Motor

ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)

Print Back
Axial fans use a propeller to create a flow of air the direction of the axis of rotation. Because they create a large airflow, axial fans are optimal for a wide variety of cooling and other airflow needs.
  • 100,000 hour life expectancy

Unit of Measure

Specifications

Lead Time1 Contact your local sales office.
This Item cannot be cancelled or returned.

Fan Type

Axial Flow

Frame Size

4.69 in

Thickness

1 in.

Function

Stall Alarm - Electronic

Power Supply

24 VDC

Connection Type

Lead Wire

Current (A)

0.30

Type

E Type (Long Life)

Speed (r/min)

3000

Max. Air Flow

95.3 CFM  

Max. Static Pressure

0.281 inH2O  

Noise Level

46 dB (A)

Components

MDE1225-24L (Fan Unit)
FG12D (Finger Guard)
M4 x 40mm (1.57 in.) (Mounting Screws)

Fan Kit

Fan, Finger Guard, Mounting Screws

RoHS Compliant

These products do not contain substances that exceed the regulation values in the RoHS Directive.

Safety Standards

DEMCO UL CE

CE Marking

EMC Directives

Insulation Resistance

10 MΩ or more when 250 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

Sufficient to withstand 500V at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

18ºF (10ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

Built-in Overheat Protection Circuit

Ambient Temperature Range

14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

85% or less (noncondensing)

Alarm Specifications

Alarm Type

Electronic

Alarm Activation Speed

When locked

Output Mode

Open-collector output

Output Condition

Operation: L level (Internal transistor ON)
When locked: H level (Internal transistor OFF)

Maximum Rating

Maximum applied voltage: 30 VDC max.
Maximum current: 5 mA max.

Delay Function

Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 1 second.

Circuit Connection


Circuit Connection

Dimensions


 

 

Airflow


 

Connection


 

System


 

  • 1 Quoted Ship Date for orders placed before 12:00 pm PST. Quantities may affect Shipping Date.