Oriental Motor

ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)

Print Back
This item has been discontinued. Please contact our technical support team for a replacement.

Fan Kit

Unit of Measure

Specifications

Product Line

ORIX®

Fan Type

Axial Flow

Frame Size

7.09 in

Power Supply

Single-Phase 220/230 VAC

Frequency

50 Hz60 Hz

Current

0.4 A [200 VAC, 50 Hz] 0.5 A [200/230 VAC, 60 Hz]

Function

Low Speed Alarm - Electronic

Connection Type

Connector

Speed (r/min)

2850 [200 VAC, 50 Hz]
3300 [200 VAC, 60 Hz]
3350 [230 VAC, 60 Hz]

Max. Air Flow

388 CFM [200 VAC, 50 Hz]
452 CFM [200/230 VAC, 60 Hz]  

Max. Static Pressure

0.786 inH2O [200 VAC, 50 Hz]
0.982 inH2O [200/230 VAC, 60 Hz]  

Noise Level

56 dB [A] [200 VAC, 50 Hz]
60 dB [A] [200 VAC, 60 Hz]
61 dB [A] [230 VAC, 60 Hz]

Components

MRS18-DMH (Fan Unit)
FG18D (Finger Guard)
M5 x 20 mm (0.79 in.) (Mounting Screws)

Fan Kit

Fan, Finger Guard, Mounting Screws

RoHS Compliant

Yes

Safety Standards

cUL EN CE

CE Marking

Low Voltage Directives

Insulation Resistance

100 MΩ or more when 500 VDC is applied between the windings and the frame under normal ambient temperature and humidity.

Dielectric Strength

Sufficient to withstand 1.5 kV at 50Hz applied between the windings and the frame for 1 minute under normal ambient temperature and humidity.

Temperature Rise

54ºF (30ºC) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity.

Insulation Class

Class E (248ºF [120ºC]), Recognized as Class A (221ºF [105ºC]) by UL and CSA standards.

Overheat Protection

Built-in thermal protector (automatic reset type)
Operating temperature, open: 248ºF±9ºF (120ºC±5ºC), close: 170.6ºF±27ºF (77ºC±15ºC)

Ambient Temperature Range

14ºF ~ 140ºF (-10ºC ~ 60ºC)

Ambient Humidity

85% or less (noncondensing)

Alarm Specifications

Alarm Type

Electronic

Alarm Activation Speed

1800 ± 300 r/min

Output Mode

Open-collector output

Output Condition

Normal operation: L level (Internal transistor ON)
Alarm output: H level (Internal transistor OFF)

Maximum Rating

Maximum applied voltage: 30 VDC max.
Maximum current: 5 mA max.

Delay Function

Not built-in: External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be at least 1 second.

Circuit Connection


Circuit Connection

Dimensions


 

 

Airflow


 

Connection