ORIENTAL MOTOR U.S.A. Corp.
570 Alaska Avenue
Torrance, CA 90503
1-800-GO-VEXTA (468-3982)
Items |
![]() MF915-BC 5.91 in. (150 mm) Cross Flow Fan Web Price $133.00
|
![]() MF915-DC 5.91 in. (150 mm) Cross Flow Fan Web Price $147.00
|
![]() MF915B-BC 5.91 in. (150 mm) Cross Flow Fan Web Price $133.00
|
![]() MF915B-DC 5.91 in. (150 mm) Cross Flow Fan Web Price $147.00
|
||||
Frame Size | - 3.54 in | |||||||
Impeller Length | - 5.91 in. | |||||||
Motor Mount | - Left | - Left | - Right | - Right | ||||
Power Supply | - Single-Phase 100/110/115 VAC | - Single-Phase 200/220/230 VAC | - Single-Phase 100/110/115 VAC | - Single-Phase 200/220/230 VAC | ||||
Frequency | - 50 Hz60 Hz | |||||||
Current | - 0.35 A [100 VAC, 50 Hz] 0.45 A [100/110/115 VAC, 60 Hz] | - 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz] | - 0.35 A [100 VAC, 50 Hz] 0.45 A [100/110/115 VAC, 60 Hz] | - 0.2 A [200/230 VAC, 50 Hz] 0.25 A [200/220/230 VAC, 60 Hz] | ||||
Speed (r/min) |
-
2650 [100 VAC, 50 Hz] 2950 [100 VAC, 60 Hz] 3200 [110 VAC, 60 Hz] 3250 [115 VAC, 60 Hz] |
-
2650 [200 VAC, 50 Hz] 2800 [230 VAC, 50 Hz] 2950 [200 VAC, 60 Hz] 3200 [220 VAC, 60 Hz] 3250 [230 VAC, 60 Hz] |
-
2650 [100 VAC, 50 Hz] 2950 [100 VAC, 60 Hz] 3200 [110 VAC, 60 Hz] 3250 [115 VAC, 60 Hz] |
-
2650 [200 VAC, 50 Hz] 2800 [230 VAC, 50 Hz] 2950 [200 VAC, 60 Hz] 3200 [220 VAC, 60 Hz] 3250 [230 VAC, 60 Hz] |
||||
Max. Air Flow |
-
120 CFM [100 VAC, 50 Hz] 131 CFM [100 VAC, 60 Hz] 141 CFM [110 VAC, 60 Hz] 145 CFM [115 VAC, 60 Hz] |
-
120 CFM [200 VAC, 50 Hz] 127 CFM [230 VAC, 50 Hz] 131 CFM [200 VAC, 60 Hz] 141 CFM [220 VAC, 60 Hz] 145 CFM [230 VAC, 60 Hz] |
-
120 CFM [100 VAC, 50 Hz] 131 CFM [100 VAC, 60 Hz] 141 CFM [110 VAC, 60 Hz] 145 CFM [115 VAC, 60 Hz] |
-
120 CFM [200 VAC, 50 Hz] 127 CFM [230 VAC, 50 Hz] 131 CFM [200 VAC, 60 Hz] 141 CFM [220 VAC, 60 Hz] 145 CFM [230 VAC, 60 Hz] |
||||
Max. Static Pressure |
-
0.353 inH2O [100 VAC, 50 Hz] 0.509 inH2O [100 VAC, 60 Hz] 0.529 inH2O [110/115 VAC, 60 Hz] |
-
0.353 inH2O [200 VAC, 50 Hz] 0.369 inH2O [230 VAC, 50 Hz] 0.509 inH2O [200 VAC, 60 Hz] 0.529 inH2O [220/230 VAC, 60 Hz] |
-
0.353 inH2O [100 VAC, 50 Hz] 0.509 inH2O [100 VAC, 60 Hz] 0.529 inH2O [110/115 VAC, 60 Hz] |
-
0.353 inH2O [200 VAC, 50 Hz] 0.369 inH2O [230 VAC, 50 Hz] 0.509 inH2O [200 VAC, 60 Hz] 0.529 inH2O [220/230 VAC, 60 Hz] |
||||
Noise Level |
-
60 dB (A) [100 VAC, 50 Hz] 63 dB (A) [100 VAC, 60 Hz] 64 dB (A) [110/115 VAC, 60 Hz] |
-
60 dB (A) [200 VAC, 50 Hz] 61 dB (A) [230 VAC, 50 Hz] 63 dB (A) [200 VAC, 60 Hz] 64 dB (A) [220/230VAC, 60 Hz] |
-
60 dB (A) [100 VAC, 50 Hz] 63 dB (A) [100 VAC, 60 Hz] 64 dB (A) [110/115 VAC, 60 Hz] |
-
60 dB (A) [200 VAC, 50 Hz] 61 dB (A) [230 VAC, 50 Hz] 63 dB (A) [200 VAC, 60 Hz] 64 dB (A) [220/230VAC, 60 Hz] |
||||
Safety Standards | - UL CSA EN CE | |||||||
|